IFP50-3 RS-232 Protocols

From ViewSonic Documentation
Jump to: navigation, search

RS-232 Protocol

This document describes the hardware interface spec and software protocols of RS-232 interface communication between ViewSonic LFD and PC or other control units with RS-232 protocol.

The protocol contains three command sections:

  • Set-Function
  • Get-Function
  • Remote control pass-through mode
NOTE: Below, “PC” represents all the control units that can send or receive the RS-232 protocol command.

Description

RS-232 Hardware Specification
ViewSonic LFD communication port on the rear side:

  1. Connector type: DSUB 9-Pin Male (or 3.5 mm barrel connector)
  2. Use of crossover (null modem) cable for connection
  3. Pin Assignment:
Pin # Signal Remark
Female DSUB 9-Pin 1 NC
2 RXD Input to Display
3 TXD Output to Display
4 NC
5 GND
Male DSUB 9-Pin 6 NC
7 NC
8 NC
9 NC Provide +5V/2A power for external specific dongle *3.0
frame GND
Item Signal Remark
3.5 mm barrel connector
(alternative for limited space)
Tip TXD Output to Display
Ring RXD Input to Display
Sleeve GND