IFP55G1 RS-232 Protocols: Difference between revisions
From ViewSonic Documentation
Created page with "<noinclude> <div class="noprint"> <div style="top:1px;width:auto;" class="nomobile"> <div class="grid-container"> <div class="item1" style="text-align:center; font-size:16; background-color:#DB0025; font-weight:bold; color:#ffffff;">{{PAGENAME}}</div> <div class="grid-item">Introduction </div> <div class="grid-item">Remote Control </div> <div class="grid-item">Using Gestures</div> <d..." |
No edit summary |
||
| (6 intermediate revisions by the same user not shown) | |||
| Line 9: | Line 9: | ||
<div class="grid-item">[[IFP55G1_Connecting_Devices|Connecting Devices]]</div> | <div class="grid-item">[[IFP55G1_Connecting_Devices|Connecting Devices]]</div> | ||
<div class="grid-item">[[IFP55G1_Using_the_ViewBoard|Using the ViewBoard]] </div> | <div class="grid-item">[[IFP55G1_Using_the_ViewBoard|Using the ViewBoard]] </div> | ||
<div class="grid-item">[[IFP55G1_On-Screen | <div class="grid-item">[[IFP55G1_On-Screen Display_Menu_Tree|On-Screen Display Menu Tree]] </div> | ||
<div class="grid-item">[[IFP55G1_On-Screen_Display_Operation|On-Screen Display Operation]] </div> | <div class="grid-item">[[IFP55G1_On-Screen_Display_Operation|On-Screen Display Menu Operation]] </div> | ||
<div class="grid-item">[[IFP55G1_RS-232_Protocols|RS-232 Protocols]]</div> | <div class="grid-item">[[IFP55G1_RS-232_Protocols|RS-232 Protocols]]</div> | ||
<div class="grid-item">[[IFP55G1_Specifications|Specifications]]</div> | <div class="grid-item">[[IFP55G1_Specifications|Specifications]]</div> | ||
| Line 21: | Line 21: | ||
</div> | </div> | ||
</noinclude> | </noinclude> | ||
=RS-232= | |||
This document describes the hardware interface spec and software protocols of RS-232 interface communication between ViewSonic LFD and PC or other control units with RS-232 protocol. | |||
The protocol contains three command sections: | |||
* Set-Function | |||
* Get-Function | |||
* Remote control pass-through mode | |||
{{Note|Below, “PC” represents all the control units that can send or receive the RS-232 protocol command.}} | |||
==Description== | |||
===RS-232 Hardware Specification=== | |||
ViewSonic LFD communication port on the rear side: | |||
# Connector type: DSUB 9-Pin Male (female or 3.5 mm barrel connector) | |||
# Use of crossover (null modem) cable for connection | |||
# Pin Assignment: | |||
{| class="wikitable" style="text-align:center; background-color:#ffffff; width:60%;" | |||
|- | |||
! style="background-color:#db0025;" | | |||
! style="font-weight:bold; background-color:#db0025; color:#ffffff;"|Pin # | |||
! style="font-weight:bold; background-color:#db0025; color:#ffffff;"|Signal | |||
! style="font-weight:bold; background-color:#db0025; color:#ffffff;"|Remark | |||
|- | |||
| style="font-weight:bold;" | Male DSUB 9-Pin (preferred) | |||
| 1 | |||
| NC | |||
| style="text-align:left;" | | |||
|- | |||
| rowspan="4" style="text-align:center;" | <div class="res-img">[[File:Male_DSUB.png|150px|link=]]</div> | |||
| 2 | |||
| RXD | |||
| Input to Display | |||
|- | |||
| 3 | |||
| TXD | |||
| Output to Display | |||
|- | |||
| 4 | |||
| NC | |||
| rowspan="5" | | |||
|- | |||
| 5 | |||
| GND | |||
|- | |||
| style="font-weight:bold;" | Female DSUB 9-Pin | |||
| 6 | |||
| NC | |||
|- | |||
| rowspan="4" style="font-weight:bold;" | <div class="res-img">[[File:Female_DSUB.png|150px|link=]]</div> | |||
| 7 | |||
| NC | |||
|- | |||
| 8 | |||
| NC | |||
|- | |||
| 9 | |||
| NC | |||
| | |||
|- | |||
| frame | |||
| GND | |||
| style="text-align:left;" | | |||
|} | |||
{| class="wikitable" style="text-align:center; background-color:#ffffff; width:60%;" | |||
|- | |||
! style="background-color:#db0025;" | | |||
! style="font-weight:bold; background-color:#db0025; color:#ffffff;"|Item | |||
! style="font-weight:bold; background-color:#db0025; color:#ffffff;"|Signal | |||
! style="font-weight:bold; background-color:#db0025; color:#ffffff;"|Remark | |||
|- | |||
| style="font-weight:bold;" | 3.5 mm barrel connector<br />(alternative for limited space) | |||
| Tip | |||
| TXD | |||
| Output from Display | |||
|- | |||
| rowspan="2" style="text-align:center;" | <div class="res-img">[[File:IFP52_Barrel_Connector.jpg|50px|link=]]</div> | |||
| Ring | |||
| RXD | |||
| Input to Display | |||
|- | |||
| Sleeve | |||
| GND | |||
| | |||
|} | |||
===LAN Hardware Specification=== | |||
ViewSonic LFD communication port on the rear side: | |||
# Connector type: 8P8C RJ45 | |||
# Pin assignment: | |||
{| class="wikitable" style="text-align:center; background-color:#ffffff; width:60%;" | |||
|- | |||
! style="background-color:#db0025;" | | |||
! style="font-weight:bold; background-color:#db0025; color:#ffffff;"|Pin # | |||
! style="font-weight:bold; background-color:#db0025; color:#ffffff;"|Signal | |||
! style="font-weight:bold; background-color:#db0025; color:#ffffff;"|Remark | |||
|- | |||
| rowspan="9" style="font-weight:bold;" | <div class="res-img">[[File:LAN_Spec.png|170px|link=]]</div> | |||
| 1 | |||
| TX+ | |||
| Output from Display | |||
|- | |||
| 2 | |||
| TX- | |||
| Output from Display | |||
|- | |||
| 3 | |||
| RX+ | |||
| Input to Display | |||
|- | |||
| 4 | |||
| BI_D3+ | |||
| For 1G case | |||
|- | |||
| 5 | |||
| BI_D3- | |||
| For 1G case | |||
|- | |||
| 6 | |||
| RX- | |||
| Input to Display | |||
|- | |||
| 7 | |||
| BI_D4+ | |||
| For 1G case | |||
|- | |||
| 8 | |||
| BI_D4- | |||
| For 1G case | |||
|- | |||
| frame | |||
| GND | |||
| style="text-align:left;" | | |||
|} | |||
====RS-232 Communication Setting==== | |||
* Baud Rate Select: 9600bps (fixed) | |||
* Data bits: 8 bits (fixed) | |||
* Parity: None (fixed) | |||
* Stop Bits: 1(fixed) | |||
====LAN Communication Setting==== | |||
* Type: Ethernet | |||
* Protocol: TCP/IP | |||
* Port: 7142 | |||
* WOL Port: 9 (fixed) for UDP | |||
* Cross subnet: No | |||
* Logon Credentials: No | |||
====Command Message Reference==== | |||
PC sends to LFD command packet followed by “CR”. Every time PC sends control command to Display, the Display shall respond as follows: | |||
# If the message is received correctly it will send “+” (02Bh) followed by “CR” (00Dh) | |||
# If the message is received incorrectly it will send “-” (02Dh) followed by “CR” (00Dh) | |||
{{#seo: | |||
|title=ViewSonic ViewBoard | |||
|title_mode=append | |||
|keywords=ViewSonic, ViewBoard, IFPG1 Protocols, RS-232, RS232, IFP55G1 | |||
|description=RS-232 Protocols for the IFP55G1 ViewBoard. | |||
}} | |||
[[Category:IFPG1 Series]] | |||
[[Category:ViewBoard]] | |||
[[Category:IFP55G1]] | |||
Latest revision as of 09:44, 25 June 2024
RS-232
This document describes the hardware interface spec and software protocols of RS-232 interface communication between ViewSonic LFD and PC or other control units with RS-232 protocol.
The protocol contains three command sections:
- Set-Function
- Get-Function
- Remote control pass-through mode
Note: Below, “PC” represents all the control units that can send or receive the RS-232 protocol command.
Description
RS-232 Hardware Specification
ViewSonic LFD communication port on the rear side:
- Connector type: DSUB 9-Pin Male (female or 3.5 mm barrel connector)
- Use of crossover (null modem) cable for connection
- Pin Assignment:
| Pin # | Signal | Remark | |
|---|---|---|---|
| Male DSUB 9-Pin (preferred) | 1 | NC | |
| 2 | RXD | Input to Display | |
| 3 | TXD | Output to Display | |
| 4 | NC | ||
| 5 | GND | ||
| Female DSUB 9-Pin | 6 | NC | |
| 7 | NC | ||
| 8 | NC | ||
| 9 | NC | ||
| frame | GND |
| Item | Signal | Remark | |
|---|---|---|---|
| 3.5 mm barrel connector (alternative for limited space) |
Tip | TXD | Output from Display |
| Ring | RXD | Input to Display | |
| Sleeve | GND |
LAN Hardware Specification
ViewSonic LFD communication port on the rear side:
- Connector type: 8P8C RJ45
- Pin assignment:
| Pin # | Signal | Remark | |
|---|---|---|---|
| 1 | TX+ | Output from Display | |
| 2 | TX- | Output from Display | |
| 3 | RX+ | Input to Display | |
| 4 | BI_D3+ | For 1G case | |
| 5 | BI_D3- | For 1G case | |
| 6 | RX- | Input to Display | |
| 7 | BI_D4+ | For 1G case | |
| 8 | BI_D4- | For 1G case | |
| frame | GND |
RS-232 Communication Setting
- Baud Rate Select: 9600bps (fixed)
- Data bits: 8 bits (fixed)
- Parity: None (fixed)
- Stop Bits: 1(fixed)
LAN Communication Setting
- Type: Ethernet
- Protocol: TCP/IP
- Port: 7142
- WOL Port: 9 (fixed) for UDP
- Cross subnet: No
- Logon Credentials: No
Command Message Reference
PC sends to LFD command packet followed by “CR”. Every time PC sends control command to Display, the Display shall respond as follows:
- If the message is received correctly it will send “+” (02Bh) followed by “CR” (00Dh)
- If the message is received incorrectly it will send “-” (02Dh) followed by “CR” (00Dh)