IFP75G1 RS-232 Protocols

From ViewSonic Documentation
Jump to: navigation, search

RS-232

This document describes the hardware interface spec and software protocols of RS-232 interface communication between ViewSonic LFD and PC or other control units with RS-232 protocol.

The protocol contains three command sections:

  • Set-Function
  • Get-Function
  • Remote control pass-through mode
Note: Below, “PC” represents all the control units that can send or receive the RS-232 protocol command.

Description

RS-232 Hardware Specification

ViewSonic LFD communication port on the rear side:

  1. Connector type: DSUB 9-Pin Male (female or 3.5 mm barrel connector)
  2. Use of crossover (null modem) cable for connection
  3. Pin Assignment:
Pin # Signal Remark
Male DSUB 9-Pin (preferred) 1 NC
2 RXD Input to Display
3 TXD Output to Display
4 NC
5 GND
Female DSUB 9-Pin 6 NC
7 NC
8 NC
9 NC
frame GND
Item Signal Remark
3.5 mm barrel connector
(alternative for limited space)
Tip TXD Output from Display
Ring RXD Input to Display
Sleeve GND

LAN Hardware Specification

ViewSonic LFD communication port on the rear side:

  1. Connector type: 8P8C RJ45
  2. Pin assignment:
Pin # Signal Remark
1 TX+ Output from Display
2 TX- Output from Display
3 RX+ Input to Display
4 BI_D3+ For 1G case
5 BI_D3- For 1G case
6 RX- Input to Display
7 BI_D4+ For 1G case
8 BI_D4- For 1G case
frame GND

RS-232 Communication Setting

  • Baud Rate Select: 9600bps (fixed)
  • Data bits: 8 bits (fixed)
  • Parity: None (fixed)
  • Stop Bits: 1(fixed)

LAN Communication Setting

  • Type: Ethernet
  • Protocol: TCP/IP
  • Port: 7142
  • WOL Port: 9 (fixed) for UDP
  • Cross subnet: No
  • Logon Credentials: No

Command Message Reference

PC sends to LFD command packet followed by “CR”. Every time PC sends control command to Display, the Display shall respond as follows:

  1. If the message is received correctly it will send “+” (02Bh) followed by “CR” (00Dh)
  2. If the message is received incorrectly it will send “-” (02Dh) followed by “CR” (00Dh)